If your state tests on the Uniform Plumbing Code, start here. Every question below is based on the UPC, and many of them hit the rules where the UPC and the IPC give different answers.

Those differences are where people lose points. A number you read online might be right for the IPC and wrong for your exam. These questions will show you which ones you have mixed up.

  1. Question 1 of 15

    Under the 2024 UPC, an appliance is connected to a metallic vent that terminates above a roofline. What does Section 1212.1 provide about CSST at that appliance?

    Show answerHide answer

    Answer: B. CSST shall not be directly routed into the metallic appliance enclosure, and shall connect only to appliances that are fixed in place

    CSST shall not be DIRECTLY ROUTED into a metallic appliance enclosure where the appliance is connected to a metallic vent that terminates above a roofline, and CSST shall connect only to appliances FIXED IN PLACE. The concern is a lightning path: a metallic vent above the roof is an attractive point of strike, and CSST entering the metal cabinet it is bonded to gives the energy somewhere to arc. The provision restricts the routing rather than banning CSST from such appliances, which is the overstatement in banning CSST outright, and the bonding jumper is required in any event under Section 1211.2.

  2. Question 2 of 15

    Under the UPC, what is required of a receptor that takes the discharge of indirect waste pipes?

    Show answerHide answer

    Answer: A. Shaped to prevent splashing, and readily accessible

    The receptor is approved for the use proposed, shaped and sized to prevent splashing or flooding, and located where it is readily accessible for inspection and cleaning. A receptor that splashes spreads whatever it receives around the room, and one nobody can reach never gets cleaned.

  3. Question 3 of 15

    Under the UPC, how many slip joint fittings are permitted on the outlet side of a trap?

    Show answerHide answer

    Answer: B. A maximum of one

    A maximum of one approved slip joint fitting is permitted on the outlet side of a trap, and no tubing trap may be installed without a listed tubing trap adapter. The other model code instead names the locations where slip joints may sit. Same concern about concealed mechanical joints, expressed two different ways.

  4. Question 4 of 15

    Under UPC Section 608.2, an approved expansion tank is installed in the cold water distribution piping downstream of each regulator for what stated purpose?

    Show answerHide answer

    Answer: D. To prevent pressure exceeding 80 psi from developing due to thermal expansion

    Section 608.2 requires the tank to prevent pressure exceeding 80 psi from developing due to thermal expansion. The figure is the same 80 psi the section uses as the trigger for fitting the regulator, which is the tidy part of the arrangement: the regulator brings the building down to 80 psi, fitting it closes the system, and the tank is what keeps the building at or below 80 psi once the heater starts cycling.

  5. Question 5 of 15

    UPC 312.6 Freezing Protection covers pipe outside a building, in attics or crawl spaces, or in an exterior wall. What does it require?

    Show answerHide answer

    Answer: B. Adequate provision against freezing where necessary

    Section 312.6 requires adequate provision, where necessary, to protect such pipe from freezing. It sets no burial depth, no insulation thickness and no particular method. Depth for buried water piping is a separate requirement in Chapter 6, which is where a candidate should go looking for it.

  6. Question 6 of 15

    Under the 2024 UPC, which of these does the UPC provide as a separately headed venting method?

    Show answerHide answer

    Answer: A. Special venting for island fixtures

    Special venting for island fixtures, at Section 909. The other three have no section heading of their own: individual venting is the default that Sections 901.2, 1002.2 and 1004.1 produce together, common venting is sized inside vertical wet venting at Section 908.1.2 rather than under its own heading, and loop venting is not a term this code uses at all.

  7. Question 7 of 15

    Under UPC Section 905.3, where two vent pipes converge, at what point may they be connected to each other?

    Show answerHide answer

    Answer: D. Not less than 6 in. above the flood-level rim of the fixture each one serves

    Each vent pipe must rise to not less than 6 in. above the flood-level rim of the plumbing fixture IT SERVES before being connected to any other vent. Each on its own account, which is the point: joining two vents low and taking the pair up together would let a stoppage at one fixture flood the vent serving the other. The datum is the flood-level rim of the fixture that vent serves, so two vents on fixtures at different heights reach their connection points at different heights.

  8. Question 8 of 15

    Under the UPC, a listed water heater's clearances come from its listing and the manufacturer's installation instructions. What else does that section require of those clearances?

    Show answerHide answer

    Answer: B. That they not interfere with combustion air, draft hood clearance and relief, or accessibility for servicing

    UPC Section 504.3.1 states that the clearances shall not be such as to interfere with combustion air, draft hood clearance and relief, and accessibility for servicing, and that listed water heaters shall be installed in accordance with their listings and the manufacturer's installation instructions. The clause matters because the listing supplies a figure and the installation has to deliver the three things that figure exists to protect. A heater sitting at exactly its listed clearance, boxed in so the draft hood cannot relieve, still fails.

  9. Question 9 of 15

    Under the 2024 UPC, how must a potable water supply tank be covered and vented?

    Show answerHide answer

    Answer: B. Tightly covered and vented per the manufacturer, with the vent screened to not less than 24 mesh

    Section 607.4 requires tanks used for potable water to be tightly covered and vented in accordance with the manufacturer's installation instructions, with the vent screened with a corrosion-resistant material of not less than number 24 mesh. A tank must breathe as its level changes, so the choice is not whether air enters but on what terms. The screen keeps insects and windblown debris out of the one deliberate opening. Section 607.5 applies the same mesh to the overflow, which must be not less than 16 square inches.

  10. Question 10 of 15

    Under the 2024 UPC, a vented flow control is installed ahead of a hydromechanical grease interceptor. Which of these does the code require?

    Show answerHide answer

    Answer: C. That no system vent lie between the flow control and the interceptor inlet

    That NO SYSTEM VENT lie between the flow control and the grease interceptor INLET. Section 1014.2 of the 2024 UPC requires the vented flow control device to be located so that no system vent sits in that stretch, and the reason is that a vent there would admit air downstream of the control and let the flow accelerate again before reaching the interceptor, defeating the control. The same section disposes of the other three options in terms: no flow control device having ADJUSTABLE OR REMOVABLE PARTS shall be approved, and the vent or air inlet shall connect with the sanitary drainage vent system or terminate through the roof and SHALL NOT terminate to the free atmosphere inside the building.

  11. Question 11 of 15

    Under the 2024 UPC, where is a subsurface irrigation field installed?

    Show answerHide answer

    Answer: C. Below finished grade, within the topsoil

    BELOW FINISHED GRADE, WITHIN THE TOPSOIL. That is the UPC definition of a Subsurface Irrigation Field. Both halves carry weight and they pull in different directions, which is what makes the definition precise. Below grade keeps untreated gray water away from contact. Within the topsoil keeps it in the biologically active layer where plant roots and soil organisms can take up and break down what it carries, and where plants can actually use it. Going deeper would satisfy the first half and defeat the second, which is why the UPC defines a separate subsoil irrigation field for deep-rooted planting rather than treating depth as a free choice.

  12. Question 12 of 15

    Under UPC Section 703.3, where is an alternate method of sizing drainage piping found?

    Show answerHide answer

    Answer: B. In Appendix C

    Appendix C. Section 703.3 states that for an alternate method of sizing drainage piping, see Appendix C. Knowing the alternate exists matters more than knowing its contents at this level, because a design sized by it will not match Table 703.2 and an inspector or an examiner may expect you to recognise why rather than to assume an error.

  13. Question 13 of 15

    Under 2024 UPC Section 603.4.4, a designer proposes a direct connection between potable water piping and a sewer-connected waste, protected by a reduced pressure principle assembly. Is that acceptable?

    Show answerHide answer

    Answer: C. No; such connections are not permitted to exist under any condition, with or without protection

    Section 603.4.4 states that direct connections between potable water piping and sewer-connected wastes shall not be permitted to exist under any condition, with or without backflow protection. That last clause is unusual and deliberate: most of the code is a graded response where a bigger hazard calls for a better device, and here the code steps outside that logic entirely. Where potable water must discharge to the drainage system, the section requires an approved air gap of two pipe diameters of the supply inlet, and in no case less than 1 inch.

  14. Question 14 of 15

    Under the UPC, copper tubing is run under a concrete floor slab. How are joints treated?

    Show answerHide answer

    Answer: A. No joints where possible, brazed where permitted

    Copper tubing under a slab is installed without joints where possible, and where joints are permitted they are brazed with wrought copper fittings. Brazing rather than soldering reflects that the joint is unreachable once the slab is poured, so it is made to the stronger standard. Mechanical joints under a slab are the opposite of what the section allows.

  15. Question 15 of 15

    Under the 2024 UPC, what residual water pressure must the supply provide after friction and other losses are allowed for?

    Show answerHide answer

    Answer: A. Not less than 15 psi, or more where a fixture or fitting requires more

    Section 608.1 states that where the main will not provide a residual pressure of not less than 15 psi after allowing for friction and other pressure losses, a tank and pump or other means of providing 15 psi shall be installed. It then adds that where fixtures or fittings are installed which require a residual pressure exceeding 15 psi, that higher pressure shall be provided. So 15 psi is a floor that individual fixtures can raise. This is structurally different from the other code, which publishes a flow pressure for each fixture ranging from 8 psi up to 45.

0 / 15Answer the questions above to see your score

If you missed more than a few, look at whether they were table questions or rule questions. Table misses get better with practice finding things fast in the book. Rule misses mean it is time to reread that chapter.

Not sure your state uses the UPC? Your state licensing board will tell you which code and which edition your exam is based on.

Want more questions like these?

Journeyman Plumber Pro has 1,800+ practice questions with explanations, timed practice exams, and weak-area drills.