A trap holds a little bit of water that keeps sewer gas from coming into the house. When that water disappears, you get the smell. There are five ways a trap can lose its seal, and the fix depends on which one you're dealing with.
Both codes want the seal at least 2 in. deep and no more than 4 in.
1. Self-siphonage
The fixture's own water fills the outlet and pulls the seal out right behind it. That's why S traps aren't allowed. The straight drop on the outlet starts a siphon every time the fixture drains. Making the seal deeper won't help.
2. Induced siphonage
Another fixture draining past the connection drops the pressure on this trap and sucks its seal out. Here's how you spot it: the lav loses its seal every time the toilet on the same branch flushes, even though nobody used the lav.
3. Backpressure
Water dropping down a stack squeezes the air in front of it. Down near the bottom, that pressure can push a trap seal right back up into the fixture, sometimes with bubbling or splashing. Siphonage pulls the seal down the drain. Backpressure shoves it up into the room.
4. Evaporation
A trap that never gets used slowly dries out, and it goes faster in warm, dry, or moving air. The classic example is a floor drain in a storage room nobody ever goes in. That's exactly what trap primers are for.
5. Capillary action
A rag, hair, or lint hanging over the weir wicks the water out of the trap and drips it down the drain. There's no pressure involved, so it keeps happening whether anything else in the building is running or not.
How to fix each one
- Self-siphonage and induced siphonage: proper venting, so air gets in before the pressure drops
- Backpressure: proper venting near the bottom of the stack
- Evaporation: a trap primer, or just use the drain
- Capillary action: pull out whatever is hanging over the weir
Cheat sheet
- Trap seal: at least 2 in., no more than 4 in.
- Siphonage pulls the seal down the drain, backpressure pushes it into the room
- S traps siphon themselves, which is why they're not allowed
- Evaporation hits drains nobody uses, and a trap primer fixes it
- Capillary action comes from rags, hair, or lint over the weir
Common questions
How deep does a trap seal need to be?
At least 2 in. on both codes, and no more than 4 in.
Why does my floor drain smell like sewer gas?
Usually evaporation. If nothing refills the trap, it dries out. A trap primer fixes it.
Why aren't S traps allowed?
The straight drop on the outlet starts a siphon, so the trap empties itself every time the fixture drains.
Studying for the journeyman plumber exam?
Journeyman Plumber Pro has 1,800+ practice questions with clear explanations, so you know why every answer is right.