You know that bang in the wall when the washer or dishwasher shuts off? That's water hammer. The water's moving, the valve slams shut, and all that energy turns into a pressure spike that whacks the pipe. An arrestor soaks up that spike.
Both codes want arrestors where quick-closing valves are installed. Here's what that means and how to figure out what's going on at a service call.
What causes it
Moving water has weight and momentum. When a fast valve, like the solenoid on a dishwasher or washing machine, shuts in a split second, all that water stops at once. The easy way to spot it: the bang only happens right when the valve closes.
When you need an arrestor
Both codes require an arrestor where quick-closing valves are used. Both also start with flow velocity, which is supposed to be kept in check to cut down on water hammer to begin with.
The UPC adds that the arrestor goes as close as possible to the valve causing it. The spike starts at the valve, so the closer the arrestor is, the less pipe takes the hit.
Which arrestors are allowed
The IPC wants arrestors that meet ASSE 1010. The UPC takes ASSE 1010 or PDI-WH 201. So ASSE 1010 works on both codes, but a PDI-WH 201 only arrestor works on the UPC alone.
Water hammer vs high pressure
These two get mixed up all the time, but they're different problems with different fixes.
Water hammer is a quick spike when a valve closes. You won't see it on a gauge with nothing running.
High static pressure is high all the time, at every faucet. Both codes require a pressure-reducing valve once static pressure goes over 80 psi.
When a house has both
Say a house sits at 94 psi and also bangs when the washer fills. That's two fixes: a regulator for the pressure and an arrestor near the washer for the bang. Fixing one won't fix the other.
Cheat sheet
- Water hammer is a pressure spike when a valve shuts fast
- Both codes want arrestors where quick-closing valves are used
- UPC: put it as close as you can to the valve
- ASSE 1010 works on both codes
- High static pressure is a separate problem, and you need a regulator over 80 psi
Common questions
Where should a water hammer arrestor go?
As close as you can get it to the quick-closing valve causing the bang. The UPC says this directly.
Will a pressure-reducing valve stop water hammer?
Not by itself. A PRV fixes static pressure over 80 psi. The bang from a fast-closing valve needs an arrestor.
What standard do arrestors need to meet?
ASSE 1010 works on both codes. The UPC also takes PDI-WH 201.